How to Read an Electric Meter
-
The electricity meter is a device that helps to measure the amount of electricity consumed by a tenant space or building. Your electric utility company uses the electric meter to measure the electric quantity used, which is shown on your monthly bill.
It is important to know how to read your electric meter to ensure that you don’t pay more money than you are supposed to. Staying informed can alert you to any inconsistency, help you monitor your monthly energy use, and help you decide if you need to switch your energy supplier. Here, we will show you how to calculate your electric reading and determine whether or not your electric provider is being honest with you.
Electric Meter Readings Explained: How to Read the Electric Meter
Reading an electric meter isn’t as complicated as you might think. First, there are four types of electric meters: Smart, digital, electronic, and traditional analog.
Smart Meter
For smart electric meters with a keypad you have to press the number 9. A group of 8 numbers will be displayed on the screen. The abbreviation kWh will be under them. Pressing the number 9 gives you your overall readings. If the meters record day and night separately, press 6 to get your night readings. This is indicated by the words IMP RO1. For day readings, press the 6 button again. The day reading is indicated by IMP R02.
How to Read a Smart Meter
Step | What to Do |
|---|---|
1. Watch the display cycle | Smart meters may show a display test, network status, instantaneous demand, and cumulative energy use. |
2. Find the billing register | Wait for the screen labeled kWh or the register identified by your electric utility. |
3. Record the reading | Write down the cumulative kWh number exactly as displayed. Do not record instantaneous kWh or demand. |
4. Check for multiple registers | Solar and time-of-use customers may have separate import, export, peak, or off-peak readings. Record each register listed on your bill. |
5. Confirm the date | Compare your reading with the utility reading from the same date. A later reading will normally be higher. |
Digital Meter
A digital electric meter is quite straightforward. The numbers for your reading are displayed on the screen. Copy these numbers from left to right excluding any numbers in red. Two rows of numbers on the screen mean your meter has day and night readings. Copy both rows from left to right.
How to Read a Digital Electric Meter
Step | What to Do |
|---|---|
1. Locate the numeric display | Find the screen showing the meter’s cumulative electricity use. |
2. Confirm the unit | Look for kWh, which stands for kilowatt-hours. |
3. Read from left to right | Copy the whole-number digits in the order shown. |
4. Handle decimals correctly | Record decimals only if your utility bill or meter instructions include them. |
5. Calculate your usage | Subtract the previous meter reading from the current reading. Apply any meter multiplier shown on your bill. |
Electronic Meter
An electronic electric meter displays readings the same way as a digital meter above. Two rows mean day and night readings, so copy both if you have them. If your electronic meter does not operate this way, you need to press a button to get the readings.
How to Read an Electronic Meter
Step | What to Do |
|---|---|
1. Wait for the correct screen | Electronic meters may automatically rotate through several readings and status codes. |
2. Find cumulative energy use | Look for a screen labeled kWh or the billing-register name supplied by your utility. |
3. Ignore nonbilling screens | Do not record display tests, network codes, instantaneous kW, voltage, or demand unless your utility instructs you to do so. |
4. Record the complete reading | Copy the cumulative kWh number exactly as displayed. |
5. Follow model-specific directions | If the meter has an external display button, use it only according to your utility’s instructions. Do not open or tamper with the meter. |
Traditional Analog Meter
The traditional dial or analog electric meter displays numbers in a funny way. Read these numbers from left to right. If there is an arrow in between two numbers, choose the lower number. Also, if there is an arrow between 9 and 0, choose 9, then subtract one from the number that follows. Don’t bother about the last digit on the right. A dial meter can be tricky but with time you get more familiar with it.
How to Read a Traditional Analog Meter
Step | What to Do |
|---|---|
1. Stand directly in front of the meter | Looking at the dials straight on reduces the chance of misreading. |
2. Start with the rightmost dial | Work from right to left so you can use the neighboring dial to confirm pointers resting directly on a number. |
3. Record the lower number | If a pointer is between two numbers, record the lower number. If it is between 9 and 0, record 9. |
4. Check pointers resting on a number | Look at the dial to the right. If that pointer has not passed 0, record the next lower number. |
5. Assemble the reading | After reading every dial, write the digits in their normal left-to-right order. |
KWh Meter Reading: How to Calculate Electricity Use
Subtract the previous cumulative reading from the current cumulative reading. Then apply the multiplier, if your bill shows one.
Calculation step | Example |
|---|---|
Current meter reading | 42,035 kWh |
Previous meter reading | 41,250 kWh |
Difference | 785 kWh |
Meter multiplier | × 1 |
Electricity used for the period | 785 kWh |
A kWh meter reading does not equal the final bill amount. The bill may also include fixed charges, taxes, credits, time-of-use rates, fuel adjustments, or solar export credits. Use your utility’s bill calculation, not a single advertised rate, to estimate the total.
How to Compare Your Reading With Your Utility Bill
Check | Why it matters | What to do |
|---|---|---|
Reading date | Usage continues after the utility’s read date | Compare readings taken on the same date or account for the extra days |
Actual or estimated reading | An inaccessible meter may lead to an estimate | Look for an estimate indicator and ask the utility when it will reconcile |
Register and multiplier | The wrong screen or missed multiplier changes the result | Match the bill’s register label and multiplier |
Billing-period length | A longer cycle can increase total kWh | Compare average kWh per day, not just the total |
Solar or time-of-use data | Import, export, and time periods may be billed separately | Match each meter register with the corresponding bill line |
If your bill doesn’t match the reading at any time, calculate again and call the utility company.